homeDOMOLAMINSULATING PANELSRoof panels PUR/PIRRoof panel with 2 ribs PR-2T 39/1000

CODE / ΚΩΔ.: PR-5T 39/250


Table of allowed loads 1) Single span loading 2) 3-span loading


Technical specifications


Domolam insulating panels are produced according to the standard EN 14509:2013 and have
CE marking.

THE INSULATION:
The polyurethane foam PUR is chemically neutral, non toxic and it is produced with environmental friendly technology with the use of pentane (CFC, HCFC free).
Domolam insulating panels are produced with PUR foam with reaction to fire Cs3d0 or in altenatively they are produced with polyisocyanurate foam PIR High Index, with reaction to fire Bs1d0 according to EN 13501-1, ΕΝ 11925-2 and EN 13823.The wall panels (vertical partition - EN 1364-1) have fire resistance EI30: E 60 and the roof panels (horizontal partition -EN 1365-2) have fire resistance REI30: RE 60 for the thickness 100mm,according to EN 13501-2.
Domolam roof panels are classified as BROOF(t1) according to the standard CEN / TS 1187:2013.
Both PUR and PIR High Index foam contain
a high percentage of closed cells >95% (waterproof/mould resistant) providing perfect adhesion to the supports.
Thermal conductivity factor λ=0,0215 W/mK
and its average density is 40-42 Kg/m3 according to EN 13165.
Average comression
strength 120 KPa.
Average adhession strength 140 KPa.
Average shear strength 100 KPa.

THE METALLIC SUPPORTS ARE:
-Pre-painted steel, in compliance with the EN 10169 standard, on hot dipped galvanized or aluzinc steel with yield strength 250-280 N/mm2 according to EN 10346 and EN 10143.
-Plastified anti-bacterial coated steel special for cold rooms and hygienic applications.
-Pre-painted, smooth or embossed aluminum, copper and stainless steel on demand.

JOINT TIGHTNESS:
Water Permeability: Class A, EN 12865
Air Permeability: 0,14m3/m2/h at 50 Pa, EN 12114

DIMENSIONS TOLERANCES
according to Annex D of ΕΝ 14509:

Corrugation height

±1mm

Pitch of profile

±2mm

Panel length

±10mm

Panel thickness

±2% of thickness

Squareness

0,6% useful width

Longitudinal bowing

2 mm/m - 10 mm

Camber

≤1% of width

Flatness

≤-1,5mm over 700mm

Edge waveness

±2mm over 500mm of length

Useful width

±2mm


Remarks

Slight leaking of foam from the joints, small foam vacuum or slight omissions and irregularities in the position of the gasket are acceptable, as long as the functional character of the panel is not compromised.

OVERLAPPING BY LENGTH:
For panels overlapped by length, the cleared part position Left or Right should be defined, according to the assembly direction.
LEFTRIGHT
Transportation


Long packs should be unloaded either with the use of spreader beam or long belts. Pre-painted sheets should not be dragged.


Storage

Should be tilted and covered in such a way as to ensure ventilation, in order to avoid vapor condensation and electrochemical corrosion.


Installation
After the installation, the protective film (if any) should be removed and the surface should be cleaned from cutting and drilling swarfs.
It is recommended that at least 2 fasteners should be used on each sheet and purlin, except for the top and bottom part of the sheet, where 3 are necessary.
Fastening should stop when the sheet starts deforming under the screw, to ensure the best aesthetic and static results.
The company is not responsible for any damage due to misuse of its products.


length (mm)smallbigweight (kg/m)weight (kg/m2)quantityprice per unit (€)value (€)Comments

You might also need these products

Roof panel with 2 ribs PR-2T 39/1000

Domolam panels are disposed in 4 types, according to the bearing capacity, aesthetical effect and cost saving requirements of the construction. Alternatively the panels “Domolam Agro” are produced with aluminum foil or PVC inside for agricultural or animal breading facilities.



Domolam roof panels points of excellence

1.
The innovative joints details ensure absolute water and air tightness.

2.
Produced with special ribs at the sides of the trapezoidal formations for increasing the bearing capacity of them.

3.
Combined according to their type with innovating photovoltaic cells in adhesive membrane.

4.
Disposed also specially formed for right or left overlapping by length.